Troubleshooting Guide
Problem:
Solution:
Digital display is not functioning
Turn Electronic Control Box pwer
switch ON
Check all electrical connections
Numbers on digital display start counting
up and do not stop with no load on the
rope.
Load cell is not properly connected to
the electronic control box. Verify all
connections are made and are tight
Cable puller does not stop when
programmed tension limit is reached.
TENSION LIMIT CONTROL if OFF.
Turn to the ON position.
Tension limit is not set to desired load.
Press “PAR” and then use the UP and
DOWN arrows to set the desired
value.
Puller is not plugged into the
Electronic Control Box.
Cable puller stops before line tension
reaches preset load limit programmed into
the Electronic Control Box.
Tension limit is not set to desired load.
Press “PAR” and then use the UP and
DOWN arrows to set the desired
value.
Replacement Parts
Replacement/Repair Part
Part Number
User Guide and Safety Manual
08677378
Fuse, 250 Volt-20 AMP
02289664
Switch, On/Off
02289665
Cord Load Cell
08677375
Light, Red Pilot Indicator
02289666
Alarm, Buzzer ECB
02289667
Button, Alarm Reset ECB
02289668
Char Recorder
08677372